Failure phenomenonPossible causesHandling methodReference
The temperature controller displays a negative value or a smaller valueThe positive end of the sensor is not connected correctlyJust change it and the display will return to normal
※The temperature controller displays an abnormal valueThe specification of the input sensor for the parameters of the temperature controller changes (intelligent instrumentCheck the parameters according to the operating manual of the temperature controller. If not correct, modify the value to the corresponding sensor
The sensor is disconnected or damagedReplace the sensor with one of the same specification (or contact our company)Replace the corresponding components according to the electrical schematic diagram
※The control circuit has no power supply and all operations are invalidThe fuse of the control circuit is blownReplace the fuse with one of the same specification (or contact our company)Replace the corresponding components according to the electrical schematic diagram
The power switch fails; the power button is damaged; or the power intermediate contactor is damagedReplace the switch, button, or intermediate contactor
※There is little or no air circulation in the ovenCheck whether the rotation direction of the blower motor is correctCorrect the rotation direction of the motor, and exchange any two phases of the power incoming lineDitto
Check whether the incoming power line has three-phases (lack of phase, etc.)Connect the power supply properly
Check whether the blower fuse is blown or whether the air switch is engaged or damagedReplace the fuse, engage the air switch or replaceDitto
Check whether the contactor and thermal relay controlling the blower are damagedReplace damaged components
※Heating stops after a whileCheck whether the temperature of the main temperature controller and the display temperature controller is set properlySet the required temperature
If the blower does not operate either, it is possibly caused by the action of the thermal relay of one of the motorsIn case of three-phase imbalance of the motor, change the thermal relay to one without phase failure protection, or increase the action setting current (while the motor is not hot)Ditto
※Display of or measurement by an ammeter shows that the currents of  three phases vary greatly and are unbalancedThe heating fuse is blownReplace the fuse with one of the same specificationDitto
One or more heating tubes may be damagedReplace the fuse with one of the same specification
※Heating alarm occurs frequentlyCheck whether the alarm temperature set for each instrument is too smallIncrease the alarm temperature (generally not exceeding the temperature of the main controller by more than 50 degrees)
The sensor is sometimes good and sometimes badMeasure the resistance of the sensor. Replace if it is damaged
Heating is interrupted; the heating indicator flashes and the heating temperature does not go up (intelligent control is provided)The parameters controlling output mode inside the intelligent temperature controller changeModify parameters that control the output modeUser’s manual of the instrument
The solid state is not triggered, possibly because the instrument output is disconnected or the solid state is damagedThe solid state is not triggered, possibly because the instrument output is disconnected or the solid state is damagedReplace corresponding components according to the electrical schematic diagram
Check whether there is voltage output from the regulated power supplyRepair or replace the regulated power supply
One group of the heating tubes is not working, possibly due to the action or damage of the temperature sensitive switchCheck whether the radiator is hot, and whether the cooling fan is working, or replace them
※Heating is out of controlThe main controller is damagedChange the main controllerDitto
The contactor is damaged (the contact is burnt and melted, or solid state is breakdown)Replace elements
Check whether the motor can rotate, possibly because the button may not work or the contactor may be damagedReplace failed components
The exhauster does not work properly (not available for standard models)The time relay or the   transfer switch thermal relay fails or the air switch trips (the fuse is blown)Replace failed components or engage the air switchDitto
※The blower stops automatically after running for a period of time, and cannot be turned on again. It can only be opened after a long timeThere may be motor overcurrent, and the corresponding thermal relay conducts protection actionIncrease the setting current of the thermal relay, and press the reset button once. If it is burnt out, replace itRefer to the electrical schematic diagram and component list
Air leakage is found from the door or explosion-proof windowThe asbestos rope is loose or unevenArrange or replace the asbestos rope